Entrepreneurship in Action, 21-24 Nov, online. Build a working product with AI

How Does a Heat Pump Move Heat? | How It Works

12 min read

On this page

What is the short answer?

Heat flows on its own from hot things to cold things. A heat pump makes it go the other way. It collects heat from a cold place, such as winter air outside a home, and releases it in a warm place, such as the rooms inside.

Pushing heat "uphill" takes work, usually from an electric compressor. A little electrical energy moves a lot of heat, so Natural Resources Canada says heat pumps reach typical efficiencies "well over 100%".

Definition: A heat pump is a machine that uses work, usually from an electric compressor, to move heat from a cooler place to a warmer one. Its coefficient of performance (COP) is the heat it delivers divided by the electrical energy it uses.

Why does heat need work to flow from cold to hot?

The second law of thermodynamics sets the rule. In the form named after Rudolf Clausius, heat cannot flow from a colder body to a warmer one unless work is done to make it happen, as HyperPhysics at Georgia State University puts it.

A heat pump obeys this law, because its compressor does the work. The first law of thermodynamics, the conservation of energy, keeps the books:

heat delivered indoors = heat collected outside + electrical energy used

So a heat pump can deliver more heat than the electricity it uses. An electric resistance heater, by contrast, turns each kilowatt hour (kWh) of electricity into at most 1 kWh of heat, HyperPhysics notes.

What happens inside the vapour-compression cycle?

A typical electric heat pump uses the vapour-compression cycle. A fluid called the refrigerant circulates in a sealed loop, boiling and condensing again and again.

  • Boiling point depends on pressure. A liquid boils when its vapour pressure equals the pressure around it, so lower pressure means a lower boiling point. Water boils below 100 °C at high altitude for this reason, HyperPhysics notes.
  • Latent heat. A liquid takes in a large amount of energy, the heat of vaporisation, as it turns to vapour, and gives it back when it condenses.
  1. Evaporator. Low-pressure liquid refrigerant in the outdoor coil boils below the air's temperature, so it takes in heat.
  2. Compressor. Squeezing the vapour raises its pressure and its temperature above that of the rooms.
  3. Condenser. In the indoor coil, the vapour condenses and gives up its latent heat to room air or water.
  4. Expansion valve. The pressure drops again, the refrigerant cools, and the cycle repeats.

Refrigerators and air conditioners embody the same principles, HyperPhysics notes. Many heat pumps also have a reversing valve, which controls the direction of refrigerant flow, Natural Resources Canada (NRCan) says. Reversed, the indoor coil becomes the evaporator and the machine cools the home, or melts frost off the outdoor coil.

What kinds of heat pumps are there?

  • Air-source. Heat comes from outdoor air; the US Department of Energy calls this the most common type.
  • Ground-source (geothermal). A sealed closed loop carries antifreeze through trenches 1.0 to 1.8 m deep or through bored holes; an open loop uses well water. Underground temperatures are higher than air temperatures in winter, NRCan notes.
  • Water-source. A closed loop can also lie in a pond or lake, NRCan says.

An air-to-air unit warms room air directly. An air-to-water unit heats water for radiators or underfloor pipes, a hydronic system.

Heat pump water heaters warm household water; the Department of Energy says they can be two to three times more efficient than a conventional electric water heater. In Japan, carbon dioxide heat pump water heaters, known as Eco Cute, were first sold in 2001; the Energy Conservation Center, Japan reported in June 2025 that cumulative shipments had passed 10 million.

How is a heat pump's efficiency measured?

A resistance heater has a COP of 1; HyperPhysics gives 3 to 4 as typical for a commercial heat pump.

COP depends on the temperature lift, the gap between the heat source and the heated space. A bigger lift needs more compressor work for each unit of heat. NRCan gives typical COPs for air-source units of 2.0 to 5.4 at 8 °C and 1.1 to 3.7 at −8 °C, and heating COPs of 3.2 to 4.2 for closed-loop ground-source units.

Below the balance point, where the heat pump's output equals the home's heat loss, a supplementary heater fills the gap. Most air-source units stop at a minimum operating temperature, −15 to −25 °C for newer models, NRCan says.

Physics sets a ceiling, the Carnot limit: ideal COP = Th ÷ (Th − Tc), with the hot and cold temperatures in kelvin, as an engineering formula sheet from FAMU-FSU gives it. For a whole winter, North American ratings use the heating seasonal performance factor (HSPF): seasonal heat delivered, in British thermal units, divided by the electricity used, in watt hours, NRCan explains.

Why does the choice of refrigerant matter?

Refrigerant can leak, and many refrigerants are strong greenhouse gases. Their effect is measured by global warming potential (GWP): the energy a given mass of a gas absorbs over a set period, compared with the same mass of carbon dioxide, says the US Environmental Protection Agency (EPA). Its 100-year values include R-410A at 2,088, R-32 at 675, propane (R-290) at 3.3 and carbon dioxide (R-744) at 1. The European Commission lists propane and carbon dioxide among natural refrigerants for heat pumps.

  • Kigali Amendment. Adopted in Kigali, Rwanda, on 15 October 2016, this amendment to the Montreal Protocol entered into force on 1 January 2019. UNEP's Ozone Secretariat says all countries will phase down hydrofluorocarbons (HFCs) by more than 80 per cent over 30 years.
  • EU F-gas Regulation. Regulation (EU) 2024/573 entered into force on 11 March 2024. Germany's Environment Agency says it cuts the HFC quota to zero from 2050 and bans placing some F-gas heat pumps and air conditioners on the market.

Where are heat pumps used around the world?

The International Energy Agency (IEA) found that heat pumps met around a tenth of the world's space heating needs in 2021, Carbon Brief reported. North America had the most installed and China the largest market.

  • Europe. The European Heat Pump Association, an industry body, counted, in preliminary data, about 2.62 million residential heat pumps sold in 16 countries in 2025, up from 2.38 million in 2024. Norway, Finland and Sweden each sold over 30 per 1,000 households.
  • United States. The Energy Information Administration (EIA) said in October 2025 that, in Census Bureau survey data, 42% of US households used electricity as their main space heating fuel in 2024 (all electric heating, not only heat pumps), and that better air-source heat pumps had helped raise that share, especially in colder climates.
  • United Kingdom. As of 9 November 2026, GOV.UK lists Boiler Upgrade Scheme grants in England and Wales of £7,500 towards an air-source (air-to-water), ground-source or water-source heat pump, and £2,500 towards an air-to-air one.

What are the debates about heat pumps?

  • Costs. Supporters argue that efficiency pays: Carbon Brief reported in December 2022 that the IEA found heat pumps three to five times more efficient than fossil fuel boilers, and Oxford engineers said in February 2023 that in the UK this can mean similar or lower bills, though electricity there typically costs 3 to 4 times as much as gas. Critics point to upfront costs; Britain's National Audit Office found in March 2024 that progress on home installations was slower than planned because costs remain high and awareness low.
  • Cold climates. Supporters cite a September 2023 study in Joule by Duncan Gibb and colleagues: standard units perform adequately in cold European winters, which rarely fall below −10 °C, and near −30 °C the data suggest up to double the efficiency of resistance heating, though the authors say more analysis is needed. They also caution that back-up heating may be needed in extreme cold.
  • Savings in practice. Supporters cite the Department of Energy's May 2023 statement that modern air-source heat pumps can cut electricity use by 50% compared with electric furnaces and baseboard heaters. Critics cite a 2013 Statistics Norway study that found the potential electricity savings from heat pumps in Norwegian homes completely offset by changes in consumption, such as warmer rooms.
  • Winter peaks. The Oxford team estimated that if 10% of British households switched, peak electricity demand could rise by 4 to 5%. Energy Systems & the Power Grid covers how grids meet such peaks.
  • Installers. The IEA's report warned of the need for training programmes, partly covered by public funding, Carbon Brief reported.

How does this work with real numbers?

Both examples use illustrative numbers; the COPs sit inside NRCan's ranges.

How much electricity does a day of heating take?

Take an illustrative home that needs 30 kWh of heat in a day.

Table: Illustrative electricity used for 30 kWh of heat

HeaterCOPElectricity used
Resistance heater130 ÷ 1 = 30 kWh
Heat pump, mild day330 ÷ 3 = 10 kWh
Heat pump, very cold day230 ÷ 2 = 15 kWh

At a COP of 3, the heat pump collects 30 − 10 = 20 kWh from outdoor air; at a COP of 2, it collects 15 kWh.

What is the Carnot limit for a home heat pump?

Take an illustrative delivery temperature of 35 °C. Adding 273.15 gives Th = 308.15 K.

  • Outdoor air at 7 °C: Tc = 280.15 K, so the ideal COP = 308.15 ÷ 28 ≈ 11.0.
  • Outdoor air at −10 °C: Tc = 263.15 K, so the ideal COP = 308.15 ÷ 45 ≈ 6.8.

HyperPhysics calls the Carnot value a theoretical maximum, so real machines reach only part of it. NRCan's typical range at 8 °C is 2.0 to 5.4, and an illustrative real COP of 3 at 7 °C would be about 27% of the ideal.

Where can the student go deeper in World 101?

This page follows heat from cold outdoor air into a warm room. The World 101 subject Renewable Energy looks at energy from resources that replenish themselves, used to make electricity, heat and fuel, and at what it takes to use them across whole countries.

Three related subjects take these ideas further. Matter, Energy & Forces explores matter and its states of solid, liquid and gas, the ground beneath boiling, condensing and latent heat. Energy Systems & the Power Grid follows electricity from power stations to homes, where heat pumps add winter demand. Climate Change explains how greenhouse gases trap heat and warm the planet, which is why a refrigerant's global warming potential matters.

Sources

  • HyperPhysics, Georgia State University, thermodynamics and vapour pressure pages, read 9 November 2026.
  • L. van Dommelen, FAMU-FSU College of Engineering, EML 3100 formula sheet, read 9 November 2026.
  • Natural Resources Canada, Heating and Cooling With a Heat Pump, modified 24 December 2025.
  • US Department of Energy, heat pump savings article, 30 May 2023; Building Science Education, Heat Pump Water Heaters, read 9 November 2026.
  • US EPA, Understanding Global Warming Potentials, 29 December 2025; GWP Reference Table, 2 April 2026.
  • UNEP Ozone Secretariat, Kigali Story and amendment text, read 9 November 2026 (adopted 2016, in force 2019).
  • Umweltbundesamt (German Environment Agency), on Regulation (EU) 2024/573 (zero HFC quota from 2050), 11 October 2024.
  • European Commission, Climate-friendly alternatives to HFCs, 12 March 2024.
  • Carbon Brief, 2 December 2022, on IEA, The Future of Heat Pumps, 2022 (2021 data).
  • European Heat Pump Association, news release, 2 March 2026 (2024 and 2025 sales).
  • US EIA, Today in Energy, 10 October 2025 (2024 data).
  • GOV.UK, Boiler Upgrade Scheme grant amounts, read 9 November 2026.
  • Heat Pumping Technologies, 1 July 2016 (Eco Cute since 2001); Energy Conservation Center, Japan, 10 June 2025.
  • D. Gibb, J. Rosenow, R. Lowes and N. Hewitt, Joule, 11 September 2023.
  • B. Halvorsen and B. M. Larsen, Statistics Norway Discussion Paper 737, 25 April 2013.
  • University of Oxford, Department of Engineering Science, 9 February 2023.
  • UK National Audit Office, Decarbonising home heating, 18 March 2024.

Common errors and misconceptions

  • Misconception: A heat pump turns electricity into heat, like a kettle. Correct: It moves existing heat from cold to warm; the electricity drives the compressor.
  • Misconception: Delivering more heat than the electricity used breaks energy conservation. Correct: The extra heat comes from outdoor air, ground or water.
  • Misconception: Freezing air has no heat to give. Correct: At low pressure the refrigerant boils below the air's temperature, so it still takes in heat.
  • Misconception: A heat pump's COP is a fixed number. Correct: It falls as the temperature lift grows; NRCan gives 2.0 to 5.4 at 8 °C but 1.1 to 3.7 at −8 °C.
  • Misconception: Heat pumps and air conditioners are different machines. Correct: Both use the vapour-compression cycle, and a reversing valve lets many heat pumps cool as well as heat.

Key takeaways

  • Heat flows on its own from hot to cold; the second law, in the Clausius form, says moving it from cold to hot needs work.
  • A heat pump delivers the heat it collects plus the electrical energy it uses, so its COP can exceed 1 without breaking energy conservation.
  • The refrigerant boils at low pressure in the evaporator, is compressed, condenses in the condenser and passes an expansion valve before repeating.
  • COP falls as the temperature lift grows; the ideal Carnot limit is Th ÷ (Th − Tc), and real machines reach only part of it.
  • Refrigerants differ widely in global warming potential; the Kigali Amendment and the EU F-gas Regulation phase down high-GWP hydrofluorocarbons.
  • Costs, cold weather, real savings and winter peaks are debated, with the IEA, Oxford researchers and Statistics Norway among those reporting findings.

Test yourself

Why does a heat pump need a compressor?

Heat will not flow from cold to hot on its own, so work is needed; the compressor supplies it.

Why does the refrigerant boil in cold outdoor air?

Its pressure is kept low in the evaporator, which lowers its boiling point below the air's temperature.

What does a reversing valve do?

It reverses the refrigerant flow, so the indoor coil becomes the evaporator and the machine cools the home.

A heat pump delivers 30 kWh at a COP of 3. How much heat came from outside?

It used 30 ÷ 3 = 10 kWh of electricity, so 30 − 10 = 20 kWh came from outdoor air.

What is the Carnot limit for heat delivered at 35 °C from air at 7 °C?

Th = 308.15 K and Tc = 280.15 K, so the ideal COP = 308.15 ÷ 28 ≈ 11.0.

Why do rules target refrigerants such as R-410A?

The EPA gives it a 100-year GWP of 2,088, against 1 for carbon dioxide, so its leaks warm the climate far more.

Go deeper in World 101: Renewable Energy

Write about it

Turn a question from this chapter into a paper.

The Writing Studio has a structure guide, a rubric and citation tools for 15 formats, from essays to research papers. A free account keeps up to five drafts. Learnacy Essential adds feedback from an AI writing coach and submission to The OYI Review.

Publication depends on review and is not guaranteed.